经销商 | 联系方式 |
---|---|
硅天下科技 | 13724212401、0755-28772011 |
MAX30004
Ultra-Low Power, Single-Channel Integrated Biopotential HR Detection AFE
Ultra-Low Power, Single Channel Integrated Biopotential HR Detection AFE
数据资料订阅尚在产。
点击查看特定型号的库存状况。
概述
参数规格
设计资源
质量与环境
订购
说明
The MAX30004 is a complete, biopotential, HR detection analog front-end solution for wearable applications, especially for chest straps and patches. It offers high performance for clinical and fitness applications, with ultra-low power for long battery life. The MAX30004 is a single biopotential channel providing R-R intervals for heart rate detection.
负责人MAXIM PM 张经理1372421 2401
The biopotential channel has ESD protection, EMI filtering, internal lead biasing, DC leads-off detection, ultra-low power leads-on detection during standby mode, and extensive calibration voltages for built-in self-test. Soft power-up sequencing ensures no large transients are injected into the electrodes. The biopotential channel also has high input impedance, low noise, high CMRR, programmable gain, various low-pass and high-pass filter options, and a high-resolution analog-to-digital converter. The biopotential channel is DC coupled, can handle large electrode voltage offsets, and has a fast recovery mode to quickly recover from overdrive conditions, such as defibrillation and electrosurgery.
负责人MAXIM PM 张经理1372421 2401
The MAX30004 is available in a 28-pin TQFN and 30-bump wafer-level package (WLP), operating over the 0°C to +70°C commercial temperature range.
MAX30004: Functional Diagram MAX30004: Functional Diagram 放大+
关键特性
Heart Rate Detection with Interrupt Feature Eliminates the Need to Extract and Process the ECG Data on the Microcontroller
Robust R-R Detection in High Motion Environment at Extremely Low Power
Clinical-Grade Biopotential AFE with High-Resolution Data Converter
15.5 Bits Effective Resolution with 5µVP-P Noise
Better Dry Starts Due to Much Improved Real World CMRR and High Input Impedance
Fully Differential Input Structure with CMRR > 100dB
Offers Better Common-Mode to Differential Mode Conversion Due to High Input Impedance
High Input Impedance > 500MΩ for Extremely Low Common-to-Differential Mode Conversion
Minimum Signal Attenuation at the Input During Dry Start Due to High Electrode Impedance
High DC Offset Range of ±650mV (1.8V, typ) Allows to Be Used with Wide Variety of Electrodes负责人MAXIM PM 张经理1372421 2401
High AC Dynamic Range of 65mVP-P Will Help the AFE Not Saturate in the Presence of Motion/Direct Electrode Hits
Longer Battery Life Compared to Competing Solutions
85µW at 1.1V Supply Voltage
Leads-On Interrupt Feature Keeps µC in Deep Sleep Mode with RTC Off Until Valid Lead Condition is Detected
Lead-On Detect Current: 0.7µA (typ)
Configurable Interrupts Allows the µC Wake-Up Only on Every Heart Beat Reducing the Overall System Power
High-Speed SPI Interface
Shutdown Current of 0.5µA (typ)
应用
胸带心率监测仪,适合健身应用
单导联事件监护仪,用于心率不齐检测
关键特性
Heart Rate Detection with Interrupt Feature Eliminates the Need to Extract and Process the ECG Data on the Microcontroller
Robust R-R Detection in High Motion Environment at Extremely Low Power
Clinical-Grade Biopotential AFE with High-Resolution Data Converter
15.5 Bits Effective Resolution with 5µVP-P Noise
Better Dry Starts Due to Much Improved Real World CMRR and High Input Impedance
Fully Differential Input Structure with CMRR > 100dB
Offers Better Common-Mode to Differential Mode Conversion Due to High Input Impedance
High Input Impedance > 500MΩ for Extremely Low Common-to-Differential Mode Conversion
Minimum Signal Attenuation at the Input During Dry Start Due to High Electrode Impedance
High DC Offset Range of ±650mV (1.8V, typ) Allows to Be Used with Wide Variety of Electrodes负责人MAXIM PM 张经理1372421 2401
High AC Dynamic Range of 65mVP-P Will Help the AFE Not Saturate in the Presence of Motion/Direct Electrode Hits
Longer Battery Life Compared to Competing Solutions
85µW at 1.1V Supply Voltage
Leads-On Interrupt Feature Keeps µC in Deep Sleep Mode with RTC Off Until Valid Lead Condition is Detected
Lead-On Detect Current: 0.7µA (typ)
Configurable Interrupts Allows the µC Wake-Up Only on Every Heart Beat Reducing the Overall System Power
High-Speed SPI Interface
Shutdown Current of 0.5µA (typ)
应用
胸带心率监测仪,适合健身应用
单导联事件监护仪,用于心率不齐检测